Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Int. j. cardiovasc. sci. (Impr.) ; 36: e20210261, 2023. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1448465

ABSTRACT

Abstract Degenerative aortic stenosis is currently a public health problem. Affecting the elderly population, this pathology has been showing an increasing prevalence as a direct result of the population aging. In this context, women have a greater life expectancy, corresponding to most of the population with degenerative aortic stenosis. Specific characteristics of this pathology in females are present in the diagnosis, pathophysiology, anatomical aspects, imaging and in therapeutic approach. Women present a more severe disease with less valve calcification than men, more concentric ventricular remodeling, higher transvalvular gradients, and less myocardial fibrosis. Less evident symptoms mean that these patients are referred later for surgical or percutaneous therapeutic treatment. The greater comorbidity presented by females and possibly due to the smaller body surface, bring specific aspects that affect the surgery results, leading to higher mortality rates and, more often, the prosthesis-patient mismatch. Percutaneous valve implantation is a good alternative, with better results in females, when compared to surgery, both in the treatment of native valves and in the treatment of a previously implanted bioprosthesis' dysfunction. The challenges encountered for the treatment of aortic stenosis in women and their possible solutions are described in this article, focusing on the observed difference of aortic stenosis in females and their possible solutions.

4.
Arq. bras. cardiol ; 114(2): 256-264, Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1088857

ABSTRACT

Abstract Background: The Instantaneous Wave-Free Ratio (iFR) is an invasive functional evaluation method that does not require vasoactive drugs to induce maximum hyperemia Objective: To evaluate the contribution of the iFR to the therapeutic decision-making of coronary lesions in the absence of non-invasive diagnostic methods for ischemia, or in case of discordance between these methods and coronary angiography. Method: We studied patients older than 18 years, of both sexes, consecutively referred for percutaneous treatment between May 2014 and March 2018. Coronary stenotic lesions were classified by visual estimation of the stenosis diameter into moderate (41-70% stenosis) or severe (71%-90%). An iFR ≤ 0.89 was considered positive for ischemia. Logistic regression was performed using the elastic net, with placement of stents as outcome variable, and age, sex, arterial hypertension, diabetes, dyslipidemia, smoking, family history, obesity and acute myocardial infarction (AMI) as independent variables. Classification trees, ROC curves, and Box Plot graphs were constructed using the R software. A p-value < 0.05 was considered statistically significant. Results: Fifty-two patients with 96 stenotic lesions (56 moderate, 40 severe) were evaluated. The iFR cut-off point of 0.87 showed a sensitivity of 0.57 and 1-specificity of 0.88, demonstrating high accuracy in reclassifying the lesions. Diabetes mellitus, dyslipidemia, and presence of moderate lesions with an iFR < 0.87 were predictors of stent implantation. Stents were used in 32% of lesions in patients with stable coronary artery disease and AMI with or without ST elevation (non-culprit lesions). Conclusion: The iFR has an additional value to the therapeutic decision making in moderate and severe coronary stenotic lesions, by contributing to the reclassification of lesions and decreasing the need for stenting.


Resumo Fundamento: Instantaneous Wave-Free Ratio (iFR) é um método de avaliação funcional invasiva sem necessidade de droga vasoativa para indução de hiperemia máxima. Objetivo: Analisar a contribuição do iFR na terapêutica das lesões coronarianas com ausência ou discrepância entre os métodos diagnósticos não invasivos para isquemia e a angiografia coronária. Método: Foram estudados pacientes consecutivos com 18 anos ou mais, ambos os sexos, no período de maio de 2014 a março de 2018, com lesões coronarianas classificadas, por medição da porcentagem de diâmetro da estenose através de estimativa visual, em estenoses moderadas (41-70%) ou graves (71%-90%). O iFR ≤ 0,89 foi considerado positivo para isquemia. Empregou-se regressão logística com elastic net, tendo como variável desfecho o emprego de stent, e variáveis independentes: idade, sexo, hipertensão arterial, diabetes, dislipidemia, tabagismo, história familiar, obesidade e infarto agudo do miocárdio (IAM) prévio. Foram construídas Árvores de Classificação, Curva Roc, e gráficos Box Plot com o software R. O valor de p < 0,05 foi considerado significativo. Resultados: Foram avaliados 52 pacientes com 96 lesões obstrutivas (56 moderadas, 40 graves). O ponto de corte do iFR de 0,87 apresentou sensibilidade de 0,57 e 1-especificidade de 0,88, demonstrando boa acurácia para a reclassificação das lesões. Diabetes mellitus, dislipidemia, e presença de lesão moderada, com iFR < 0,87 foram preditores do implante de stents. Foram empregados stents em 32% das lesões de portadores de doença arterial coronariana estável e IAM com e sem supra de ST (lesões não culpadas). Conclusão: O iFR contribui para a reclassificação das lesões e diminuição do emprego de stents, auxiliando na abordagem das lesões moderadas e severas.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Cardiac Catheterization/methods , Myocardial Ischemia/diagnosis , Myocardial Ischemia/physiopathology , Reference Values , Severity of Illness Index , Logistic Models , Stents , Pilot Projects , Reproducibility of Results , Sensitivity and Specificity , Coronary Angiography/methods , Statistics, Nonparametric , Atherosclerosis/diagnosis , Atherosclerosis/physiopathology , Clinical Decision-Making
5.
RELAMPA, Rev. Lat.-Am. Marcapasso Arritm ; 29(1): 29-33, jan.-mar.2016. ilus
Article in Portuguese | LILACS | ID: lil-788822

ABSTRACT

O tratamento da estenose aórtica com implante por cateter de bioprótese valvar aórtica é sabidamente eficaz. Contudo, os distúrbios de condução são complicações frequentes e associam-se a elevada taxa de implante de marcapasso definitivo. Questões referentes ao melhor modo de estimulação, ao papel do cardiodesfibrilador na profilaxia de morte súbita e ao prognóstico ainda não apresentam consenso. Relata-se, portanto, um caso de paciente que, após o implante valvar, evoluiu com bloqueio completo de ramo esquerdo agudo e bradiarritmia, insuficiência cardíaca refratária ao tratamento medicamentoso, com fração de ejeção gravemente comprometida e intolerância ao betabloqueador por bradiarritmia. Optou-se, então, pela terapia de ressincronização ao invésdo marcapasso convencional, com boa resposta clínica. A associação com cardiodesfibrilador foi descartada paraprofilaxia de morte súbita após o estudo eletrofisiológico, o qual não evidenciou instabilidade elétrica ventricular...


Treatment of aortic stenosis with valve of transcatheter implant is known to be effective. However, conduction disorders are common complications and are associated with a high permanent pacemaker implantation rate. Questions regarding the best pacing mode, the role of the defibrillator in sudden death prevention and prognosis, do not have consensus yet. We report, therefore, the case of a patient who developed complete blockage of acute left bundle branch and bradyarrhythmia, heart failure refractory to drug therapy, poor ejection fraction and intolerance to betablocker due bradyarrhythmias after valve implant. Thus, we chose resynchronizationtherapy instead of conventional pacemakers and obtained a good clinical response. The association with adefibrillator was ruled out for sudden death prevention after the electrophysiological study, which did not show ventricular electrical instability...


Subject(s)
Humans , Male , Aged , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement/methods , Cardiac Resynchronization Therapy/methods , Aortic Valve/surgery , Bundle-Branch Block/complications , Bundle-Branch Block/therapy , Death, Sudden, Cardiac , Defibrillators, Implantable , Echocardiography/methods , Heart Valve Prosthesis Implantation/methods , Electrophysiologic Techniques, Cardiac/methods
6.
Arq. bras. med. nav ; 50(1): 43-60, 1989. ilus
Article in Portuguese | LILACS | ID: lil-75311

ABSTRACT

É apresentado o caso de uma paciente do sexo feminino, com 7 anos de idade, portadora de fístula arteriovenosa pulmonar, localizada no segmento anterior do lobo superior direito, com história de cansaço e tosse. Embora apresentasse cianose, hipocratismo digital e poliglobulia, näo apresentava sinais de Doença de Rendu-Osler-Weber. Foi avaliada clínica e laboratorialmente, sendo constatado pela cintilografia pulmonar e estudo angiográfico, tratar-se de fístula arteriovenosa pulmonar do tipo complexo. Optou-se pelo tratamento emboligênico com utilizaçäo da mola de Gianturco-Wallace, após estudo cineangiográfico seletivo, o qual possibilitou análise fidedigna da localizaçäo e estrutura anatômica do complexo fistuloso. Evoluiu com reduçäo quase que imediata da cianose e aparecimento de circulaçäo pulmonar a jusante do trajeto fistuloso, que ate entäo mostrava-se inconstante, pelo fluxo preferencial do contraste através da fístula. Concluiu-se que uma avaliaçäo criteriosa do comcplexo fistuloso a luz do estudo cineangiográfico, forneceu detalhes que possibilitaram optar pela embolizaçäo terapêutica, um procedimento opcional e atrativo para muitos casos de fístulas arteriovenosas pulmonares, evitando-se assim o tratamento cirúrgico


Subject(s)
Child , Humans , Arteriovenous Fistula , Pulmonary Artery , Angiography , Embolization, Therapeutic , Arteriovenous Fistula , Arteriovenous Fistula/therapy , Radionuclide Imaging
SELECTION OF CITATIONS
SEARCH DETAIL